Passivhaus and high-performance construction: what does certification verify?

Josh Batterton ·

The distinction I draw between a certified Passivhaus and a high-performance home is the extent to which the design assumptions are tested. We might specify the same glazing, insulation and ventilation system for either home. In pursuing the Passivhaus standard, however, we need to demonstrate that those decisions, taken together, are appropriate for the building and its climate. We also need to verify that what was designed has been carried through into construction.

How does that affect the design?

If we were to use a window to compare Passivhaus and high-performance construction, I would specify quality double glazing and a well-sealed frame for either. The distinction becomes apparent when we enter the performance data for the glass and frame into the energy model. A frame that is sufficient for a home in Bellingen may be insufficient for the same design on the New England Plateau. Equally, the modelling may confirm that the less expensive of two frames is adequate. Both conclusions are useful.

The same reasoning applies to insulation, shading and the junctions between building elements. Increasing the insulation in a wall may achieve relatively little if a significant proportion of the heat is being lost through the window frames. Modelling gives us a basis for deciding where additional expenditure is warranted and where it is unlikely to make a material difference.

What gets checked during construction?

Airtightness is a good example of the limits of a specification. We can nominate a suitable membrane and draw a continuous line around the building in section. Neither tells us whether the junction behind a window was sealed properly or whether a cable installed later has compromised it.

A blower door test measures the air leakage of the building as constructed. If we test while the airtight layer is still accessible, the builder has an opportunity to locate and rectify leaks before the internal linings go on. The final test provides a measured result for certification.

What are the risks of building an airtight home without certification?

As we reduce air leakage through the building, we become more reliant on the ventilation strategy to maintain indoor air quality. Specifying a heat recovery ventilation unit tells us very little about how much fresh air reaches a bedroom overnight with the door closed, or how effectively moisture is extracted from a bathroom after a shower. As part of Passivhaus certification, the supply and extract airflows are measured, adjusted against the design and recorded for the certifier to review.

There is a related consideration in winter. We are designing for a consistently warm internal environment, and the temperature difference between inside and outside can be substantial. If the insulation is interrupted at a junction, such as the edge of a concrete slab, heat can escape more readily at that point. This is a thermal bridge. The internal surface at the junction can be considerably colder than the surrounding wall, even when the room itself is comfortable. Depending on the indoor humidity, that cold spot can support mould growth before there is any visible condensation.

This is where I see value in certification as a check and balance. The certifier reviews how thermal bridges have been accounted for in the design and whether the measured ventilation rates correspond with those intended. We can undertake the same work on an uncertified home, but it needs to be included in the scope. Otherwise, a well-insulated wall and a quality ventilation unit can both be specified without anyone assessing the coldest junction or measuring the airflow in the finished bedroom.

How do we decide whether to certify?

I would start with the project brief. If you tell me you want a home that is warm in winter, I’d want to know what that means to you. Is the priority a living room that warms quickly when you light the fire, or do you want the bedrooms to remain comfortable through a winter night with very little supplementary heating? Those are different briefs and may lead us to different decisions about the building.

Once we have defined the outcome, it becomes much easier to decide how high a priority measurable thermal comfort is for the project. If it is central to the brief, there is a strong case for pursuing Passivhaus certification: the performance targets are established from the outset and an independent certifier assesses the design and construction evidence against them. If a high-performance home without certification better suits the brief, we can agree early on which outcomes matter most and include the modelling, detailing and testing needed to assess them.

Discuss your project

Contact the studio

New homes and renovations in Bellingen and the Mid North Coast.